Radiation biodosimetry

Radiation biodosimetry
Dose (Gy) Vomiting (percent) Time to vomiting (hours) ALC day 1* Lymphocyte fall rate constant (k) Lymphocyte dicentrics (per 1000)Δ
0 0 - 2450 - 1-2
1 19 - 2160 0.126 88
2 35 4.6 1900 0.252 234
3 54 2.6 1680 0.378 439
4 72 1.7 1480 0.504 703
5 86 1.3 1310 0.63 1000
6 94 1 1150 0.756  
7 98 0.8 1010 0.881  
8 99 0.7 890 1.01  
9 100 0.6 790 1.13  
10 100 0.5 700 1.26  
Gy: absorbed whole body dose in Gray units.
* ALC day 1: absolute lymphocyte count per microL on day 1 after exposure.
¶ The lymphocyte fall rate constant is derived from a semilogarithmic plot of the absolute lymphocyte count (ALC) versus time in days, in the form of 2450 x e–kt. The time (in days) for the ALC to fall to one-half of its original value [half-time, T(1/2)] can be obtained from the following equation: T(1/2) = 0.693/k.
Δ Dicentric chromosomes are those containing two separate centromeres, caused by end-to-end recombination of two damaged chromosomes.
Modified with permission from: Waselenko JK, MacVittie TJ, Blakely WF, et al. Medical management of the acute radiation syndrome: Recommendations of the strategic national stockpile radiation working group. Ann Intern Med 2004; 140:1037. Copyright © 2004 American College of Physicians.