Characteristic |
Reentrant |
Triggered |
Automatic |
Initiation by extrastimuli and/or continuous pacing |
Yes |
Yes |
No |
Initiation by continuous pacing depends upon the rate and number of stimuli |
No |
Yes |
No |
Termination by extrastimuli |
Yes |
No |
No |
Termination by continuous pacing (overdrive) |
Yes |
Yes |
No |
Overdrive suppression of tachycardia |
No |
No |
Yes |
Overdrive enhancement of tachycardia |
Yes |
Yes |
No |
Entrainment possible |
Yes |
No |
No |
First P wave identical to P waves in arrhythmia |
No |
Sometimes |
Yes |
Warm-up or acceleration of pacemaker after onset |
No |
Sometimes |
Yes |